Oak Bluffs, MA old classifieds archive and funnies   >   By Year   >   2005   >   Ge size 3 starter 6 motor 200A 400 a 600V disconnect

Ge size 3 starter 6 motor 200A 400 a 600V disconnect


This Hoffman control panel ran (6) 25 HP motors with 90amp starters at 480 Volt, reversing three and three motors simultaneously after a brief time delay. The schedule clock and 5 Omron Button type relays are missing. Everything else is in place to run the system on an automatic, predetermined, reversing schedule. With the switch, all the other parts, starters and Nema 3R 12 enclosure, it lends itself to many applications from soft starting up to 6 separate 50 HP 480 Volt motors in some applications with the required corresponding upgrade to overload relays for such a use. Use as 3 reversing starters or modify to 6 separate controlled circuits, modify to soft/step start and more .
If you currently run GE in your factory or business then these are excellent spare parts; even comes with its own Nema type 12 3R storage cabinet. Hey close off the vents may even make Nema type 4, 4X storage cabinet, or part out for resale and gross $$Thousands.
* 6 of GE size 3 Model CR209E000ALA 90 AMP 50 HP Max 600 Volt, 50HP @ 480V to 575 Volt.
* Set up as 3 reversing starters, can be separated.
* 6 of 3 pole Overload relays CR224D310A.
5 are reset Auto or manual 1 Relay is permanently set to Auto Reset.
* 18 of heater elements C330B Adjustable to 90% to 110% or 30 amp Min to 39 amp Max Fla Ref CR123 CR123C330B c33OB
* 1 of 3' X 5' Hoffman control cabinet, Internal fuse rated for 250 Amp.
* 3 of Indicator Lamps. Lamp catalog no. 800H-QR10 Series C Sockets and Attaching Hardware. Need lenses and bulbs. 2 of indicator lamps CR103HA1 complete.
* 1 of Pilot Duty cabinet on / off switch GE CR2940U310
* 1 of THCH4 HCI TDM handle lockout main disconnect switch.TDM Handle rated Nema Type 1 3R 12 12K to match rating of cabinet.
* 1 of Time Hour meter Type 117 J17FAB19 12J4AA08A-682 R
* 1 of 1 / 70 Hp Squirrel cage blower cools cabinet. Blower has a 12 volt Dayton Model 3M625 Motor.
* 6 of control coil 110 / 120 Volt, 50 / 60 HZ 55-50136G22
* 3 of Reversing kit attachments safety inter-lockouts easily removable to use as 6 separate starters.
* 6 of CR205X Control Switch 2 Pole. 1 N.O. + 1 N.C. 250 VDC 600VAC
* 4 of 8 Pin Relay and Time delay Socket # 27E122 AMF Potter & Brumfield sockets stacked on bar. 10A 300V ea.
* 1 of 8 Pin SM8 or 8M8.C Control relay socket. RDI Reed Devices inc. 10A 300V
* 1 of Buchanan Bar 13 Post or Pole Buchanan Type BC-2067 223 Stackable Terminal Block.
* 6 of Taylor 60 Amp 600 Volt 3 pole Fuseholder (s).
* 1 of Acme Transformer Industrial Control 300 VA Type No. TA-2-81200 220 VOLT / 480V to 110V / 120V Insulation class 130.
* 1 of Buss Single Pole Fuse Holder 30A-600V
* 1 of Buss Type Two Pole Fuse Holder 30A 600 Volt
* Cabinet and all components show 1 or more of the following SA, UL listed sticker. Or stamp. NECA seal of electrical satisfaction, IBEW, UL File Ref E836* and E639*
* All 72 Direct line, Hard Silver Alloy contact surfaces inspected and are in excellent condition showing proper use and very little wear. They all look in same condition as the contact surfaces shown in the 2 pics below. After inspection each contact assembly was re-installed in original position to keep matching wear of contacts.
* Contact Surfaces not brushed up, not touched up.
* All 6 control coils tested with 120 volt
* Paint fair to poor, mechanical good to excellent condition.
Feel free to email with any questions you may have.
CR209EO CR206f0 CR209E0 CR205E0 CR205EO CR206E0 CR206 FO CR2O6 EO CR206EO F0 E0 CR306E002 CR306EOO2 CR306E0 CR306EO CR209EOOOALA CR206FO CR205E1 5550136G22 55-501336G22 55501336G22 55501336G2 55-5011336G2 55501336G 55-501336G 55-501336G3 55501336G3 run 10hp 10 15 20hp 20 25 30hp 30 40hp 40 50 or combinations thereof HP pump pumps etc.



Ge size 3 starter 6 motor 200A 400 a 600V disconnect